Performance in Action

RUBY™ advances MPI with cardiac PET to help improve your clinical decision making.

Constant Activity

Flexible infusion mode options1

Constant activity [“square-wave”] or constant flow [bolus] profiles

30mCi* Eluted Activity

Hot (New) Generator

Cold (Old) Generator

Helps to minimize detector saturation with constant activity1

Choose your infusion strategy based on clinical need

Square-wave offers consistent infusion profiles regardless of Rb82 generator life1,2

Constant activity mode maintains steady detector performance throughout

RELIABILITY

Advantages of constant activity infusion.

Consistent profiles regardless of generator life. Maintains steady activity delivery throughout the procedure.

Reproducibility1-3

Rb82 activity rate profiles remain consistent throughout the life cycle of the generator.

Reduced variability2

Controlled dosing accuracy for quantification with every study you perform.

Controlled dosing accuracy for quantification1,3

Enter the patient’s weight and the correct dose calculates automatically.

Explore More

Weight-based Dosing.

Weight-based dosing helps tailor dose delivery to each patient.

Automated calculations streamline workflow and reduce the need for manual dose adjustments.

Eliminates the need for manual readings, reporting, or recalibration between patients.

PRECISION

Increased dosing accuracy through saline push.

The exclusive saline push feature significantly increases Rb82 activity delivered to the heart and retained in the myocardium. This means better imaging with less radiation exposure to your patient.

Explore More

Saline Push

Exclusive saline push feature SIGNIFICANTLY INCREASES Rb82 ACTIVITY delivered to the heart and retained in the myocardium.4

  • 2X increase in myocardial uptake4
  • 25% increase in image SNR and CNR4

Myocardial Uptake

RUBY-FILL® saline push improves myocardial uptake for better imaging

How it Works

After dose delivery, the system automatically diverts saline past the generator and through the bypass line. Saline clears the tubing and pushes rubidium through the veins to the heart.

  1. Our peristaltic pump works continually during the patient infusion
  2. The pinch valves diverts saline through the rubidium generator to deliver the requested dose to the patient
  3. After delivery of the dose, the pinch valve activates to automatically divert saline past the generator and through the bypass line, flushing the tubing with saline
    • Saline clears the proprietary infusion tubing of the bypass line and patient line
    • Saline pushes the rubidium through the peripheral and central veins to the heart

Statement on High Level Radiation

Read More

The path forward starts here

Join us in transforming diagnostic imaging for clinicians 
and patients alike.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
  • Home
  • Meet RUBY-FILL®
  • Performance
  • Proof
  • Contact Us
  • Privacy
  • Terms
  • Opt-out
Rubyfill Rubidium Rb82 Generator Icon in red and blue

REFERENCES

  1. Klein R, Beanlands RS, deKemp RA. Quantification of myocardial blood flow and flow reserve: technical aspects. J Nucl Cardiol. 2010;17(4):555-70.
  2. Klein R, Ocneanu A, Renaud JM, Ziadi MC, Beanlands RSB, deKemp RA. Consistent tracer administration profile improves test-retest repeatability of myocardial blood flow quantification with 82Rb dynamic PET imaging. J Nucl Cardiol. 2018;25(3):929-941.
  3. Epstein NJ, Benelfassi A, Beanlands RSB, Dekemp RA. An 82Rb infusion system for quantitative perfusion imaging with 3D PET. Appl Radiat Isot. 2004;60(6):921-927.
  4. Renaud JM, Wu KY, Gardner K, Aung M, Beanlands RSB, deKemp RA. Saline-push improves rubidium-82 PET image quality. J Nucl Cardiol. 2018;26(6):1869-1874.

 

© 2026 Jubilant DraxImage Inc. dba Jubilant Radiopharma™, a Jubilant Pharma Company.

The information presented on this website is intended for U.S. audiences and is based on the U.S. FDA-approved prescribing information for RUBY-FILL® as of the date of publication. 

Warning: High Level Radiation Exposure with use of incorrect eluent and failure to follow quality control testing Procedure
Please see full prescribing information for complete boxed warning.

High Level Radiation Exposure with Use of Incorrect Eluent
Using the incorrect eluent can cause high Strontium (Sr 82) and (Sr 85) breakthrough levels (5.1)

  • Use only additive-free 0.9% Sodium Chloride Injection USP to elute the generator (2.5)
  • Immediately stop the patient infusion and discontinue the use of the affected RUBY-Full® generator if the incorrect solution is used to elute the generator (4)
  • Evaluate the patient's radiation absorded dose and monitor for the effects of radiation to critical organs such as bone marrow (2.9)

Excess Radiation Exposure with Failure to Follow the Quality Control Testing Procedure
Excess radiation exposure occurs when the levels of Sr 82 or Sr 85 in the Rubidium Rb 82 Chloride injection exceed specific limits (5.2)

  • Strictly adhere to the generator quality control testing procedure (2.6)
  • Stop using the generator if it reaches any of its Expiration Limit (2.7)
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}